LTPP Logo Long Term Pavement Performance Logo

LTPP TSSC Home

Data User's Corner





LTPP TABLE NAVIGATOR: Field View


Fields for table: TST_AC07_V2_MR_SUM

Field NameCodesData TypeUnitsTest ProtocolDescription
STATE_CODE
STATE_PROVINCENUMBER(2)

P07
Numerical code for state or province. U.S. codes are consistent with Federal Information Processing Standards.
SAMPLE_AREA_NO

VARCHAR2(5)

P07
Number used to reference all samples taken from one area of the project - used only for SPS-5, 6, and 7 project.
INST_MR_CYCLE_1

NUMBER(4,2)
GPa
P07
Instantaneous resilient modulus for load cycle 1.
INST_MR_POISSON_CALC_CYCLE_1

NUMBER(3,2)

P07
Instantaneous Poisson's ratio for load cycle 1. Calculated from raw load/deformation time histories.
INST_MR_POISSON_USED_CYCLE_1

NUMBER(3,2)

P07
Poisson's ratio used to calculate instantaneous resilient modulus for cycle 1.
TOTAL_MR_CYCLE_1

NUMBER(4,2)
GPa
P07
Total resilient modulus for load cycle 1.
TOTAL_MR_POISSON_CALC_CYCLE_1

NUMBER(3,2)

P07
Total calculated Poisson's ratio for load cycle 1.
TOTAL_MR_POISSON_USED_CYCLE_1

NUMBER(3,2)

P07
Poisson's ratio used to calculate total resilient modulus for cycle 1.
INST_MR_CYCLE_2

NUMBER(4,2)
GPa
P07
Instantaneous resilient modulus for load cycle 2.
INST_MR_POISSON_CALC_CYCLE_2

NUMBER(3,2)

P07
Instantaneous Poisson's ratio for load cycle 2. Calculated from raw load/deformation time histories.
INST_MR_POISSON_USED_CYCLE_2

NUMBER(3,2)

P07
Poisson's ratio used to calculate instantaneous resilient modulus for cycle 2.
SHRP_ID

VARCHAR2(4)

P07
Test section identification number assigned by LTPP program. Must be combined with STATE_CODE to be unique.
TOTAL_MR_CYCLE_2

NUMBER(4,2)
GPa
P07
Total resilient modulus for load cycle 2.
TOTAL_MR_POISSON_CALC_CYCLE_2

NUMBER(3,2)

P07
Total calculated Poisson's ratio for load cycle 2.
TOTAL_MR_POISSON_USED_CYCLE_2

NUMBER(3,2)

P07
Poisson's ratio used to calculate total resilient modulus for cycle 2.
INST_MR_CYCLE_3

NUMBER(4,2)
GPa
P07
Instantaneous resilient modulus for load cycle 3.
INST_MR_POISSON_CALC_CYCLE_3

NUMBER(3,2)

P07
Instantaneous Poisson's ratio for load cycle 3. Calculated from raw load/deformation time histories.
INST_MR_POISSON_USED_CYCLE_3

NUMBER(3,2)

P07
Poisson's ratio used to calculate instantaneous resilient modulus for cycle 3.
TOTAL_MR_CYCLE_3

NUMBER(4,2)
GPa
P07
Total resilient modulus for load cycle 3.
TOTAL_MR_POISSON_CALC_CYCLE_3

NUMBER(3,2)

P07
Total calculated Poisson's ratio for load cycle 3.
TOTAL_MR_POISSON_USED_CYCLE_3

NUMBER(3,2)

P07
Poisson's ratio used to calculate total resilient modulus for cycle 3.
INST_MR_AVG

NUMBER(4,2)
GPa
P07
Average instantaneous resilient modulus determined by averaging results from cycles 1, 2, and 3.
LAYER_NO

NUMBER(2)

P07
Unique sequential number assigned to pavement layers, starting with layer 1 as the deepest layer (subgrade).
INST_MR_POISSON_CALC_AVG

NUMBER(3,2)

P07
Average instantaneous calculated Poisson's ratio determined by averaging results from cycles 1, 2 and 3.
INST_MR_POISSON_USED_AVG

NUMBER(3,2)

P07
Average Poisson's ratio used to calculate the instantaneous resilient modulus value determined by averaging results from cycles 1, 2 and 3.
TOTAL_MR_AVG

NUMBER(4,2)
GPa
P07
Average total resilient modulus.
TOTAL_MR_POISSON_CALC_AVG

NUMBER(3,2)

P07
Average total calculated Poisson's ratio.
TOTAL_MR_POISSON_USED_AVG

NUMBER(3,2)

P07
Average Poisson's ratio used to calculate the total resilient modulus value.
MR_DATA_FILE_SPECIMEN_1

VARCHAR2(12)

P07
Name of file that contains load/deformation time histories used in calculation of resilient modulus for a given test temperature for specimen 1.
MR_DATA_FILE_SPECIMEN_2

VARCHAR2(12)

P07
Name of file that contains load/deformation time histories used in calculation of resilient modulus for a given test temperature for specimen 2.
MR_DATA_FILE_SPECIMEN_3

VARCHAR2(12)

P07
Name of file that contains load/deformation time histories used in calculation of resilient modulus for a given test temperature for specimen 3.
COMMENT_OTHER

VARCHAR2(40)

P07
A note used to record additional observations regarding the test, or test results.
TEST_NO
TEST_NONUMBER(2)

P07
Code number indicating sample location.
CONSTRUCTION_NO

NUMBER(2)


Event number used to relate changes in pavement structure with other time dependent data elements. This field is set to 1 when a test section is initially accepted into LTPP and is incremented with each change to the layer structure.
FIELD_SET

NUMBER(2)

P07
Sequential number indicating the field sampling event. Assigned 1 for first sample event and incremented by 1 for subsequent events.
TEST_TEMPERATURE

NUMBER(3,1)
deg C
P07
Temperature at which test was performed.
RECORD_STATUS

VARCHAR2(1)


A code indicating the general quality of the data.
LAB_CODE
LAB_CODEVARCHAR2(4)

P07
Code indicating the lab that performed the testing.